Welcome to Beijing Meizheng Bio-Tech Group

 Contact Us    Cart

/ EN

Current Position: HOMEFOOD SAFETYMilk TestRapid Test > AnticFast® Sulfonamides &Trimethoprim Rapid Test Strips
FOOD SAFETY
  • Product Name: AnticFast® Sulfonamides &Trimethoprim Rapid Test Strips
  • Views : 6
  • Quantity:  购买数量不能低于最少订购数量!

Add To Cart Immediate Inquiry

AnticFast® Sulfonamides &Trimethoprim Rapid Test Strips

Order No。: JC0196

【Intended Use】

Sulfonamides&Trimethoprim Rapid Test kit is a lateral flow assay that determines a qualitative level for the presence of sulfonamides and trimethoprim residues in raw cow’s milk. This test is designed for rapid field use or daily control in laboratories.  

Limit of Detection】 (μg/kg=ppb)

Sulfonamides

Limit of Detection (μg/kg)

sulfamethazine

10

sulfamerazine

4

sulfadiazine

3

sulfamonomethoxine

3

sulfadimethoxine

4

sulfadoxine

3

sulfametoxydiazine

4

sulfisomidine

4

sulfachlorpyridazine

5

sulfamethoxypyridazine

10

sulfabenzamide

7

sulphaquinoxaline

9

Sulfamethoxazole

20

Trimethoprim

Trimethoprim

6-8

Scope of Application

Raw cow’s milk

Kit Contents

1. Test strips: 12x8 strips (96 strips total)

2. Microwells (Reaction wells): 12x8 wells (96 wells total)

3. Pipette tips: 100/kit or disposable pipettes:100/kit

4. Microwell holder: 1

【Test Procedure】

Note: READ COMPLETELY BEFORE USE! All reagents and kit components should reach room temperature (20-25˚C) before use. Shake the milk vigorously to ensure sample homogeneity.

1. Remove the cover of the tube and take appropriate number of test strips and microwells and immediately cover the tube. Re-store the remaining components at 2-8˚C.  

2。 Place the microwells into the wells of the incubator (40 ˚C)  

3. Using a single channel pipette (Optionally, using a disposable pipette), add 200µL of milk sample to each microwell. Dissolve the coating conjugate in the microwell by pipetting the content up and down for 5 or 6 times.

4。 Incubate the sample for 2 minutes at 40˚C and then put one test strip into one well。

5. Let the test strip develop color for 5 minutes at 40˚C.  

6. Remove the absorbent pad and interpret test results within 1 minute.

【Interpretation of the Results】